mediatek consys Required properties: - compatible:Should be "mediatek,mt6735-consys". - reg: Should contain register location and length. - interrupts: Should contain interrupt.(including BGF and WDT interrupts). - clocks: The clocks needed in consys power on, provided from clock manager. - clock-names : used for sw control clock - vcnxx-supply : LDO domain for consys,provided from PMIC owner Examples: consys:consys@18070000 { compatible = "mediatek,mt6735-consys"; reg = <0x18070000 0x0200>, /*CONN_MCU_CONFIG_BASE */ <0x10212000 0x0100>, /*AP_RGU_BASE */ <0x10000000 0x2000>, /*TOPCKGEN_BASE */ <0x10006000 0x1000>; /*SPM_BASE */ interrupts = , /* BGF_EINT */ ; /* WDT_EINT */ clocks = <&scpsys SCP_SYS_CONN>,<&infrasys INFRA_CONNMCU_BUS>; clock-names = "conn","bus"; vcn18-supply = <&mt_pmic_vcn18_ldo_reg>; vcn28-supply = <&mt_pmic_vcn28_ldo_reg>; vcn33_bt-supply = <&mt_pmic_vcn33_bt_ldo_reg>; vcn33_wifi-supply = <&mt_pmic_vcn33_wifi_ldo_reg>; };